Empecemos con el Review de Reamer Irrigator Aspirator!!
RIA 2 System (Reamer Irrigator Aspirator) RIA 2 is intended for the clearing and sizing of the medullary canal, the harvesting of autograft, and the debridement of necrotic and infected tissues from the medullary canal. Designed for simplified assembly. For femur …
RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 5 3. OPEN CANAL Instruments 357.399 3.2 mm Guide Wire, 400 mm 03.010.040 12.0 mm Cannulated Awl Or 357.399 3.2 mm Guide Wire, 400 mm 357.403 6.0 mm/10.0 mm Stepped Drill Bit - Cannulated/large QC/435 mm 03.010.030 13.0 mm Protection Sleeve 03.010.031 13.0 mm/3.2 mm Wire Guide with trocar tip
The reamer-irrigator-aspirator (RIA) system has been recently developed to decrease the incidence of osseous thermal necrosis and fat embolism associated with intramedullary reaming of long bones in trauma cases. This is achieved by continuous irrigation and suction. Recently, the use of RIA has bee …
Reamer/Irrigator/Aspirator (RIA) Technique Guide Synthes 13 Button on tube assembly Rotate the locking clip until the circular notches on the locking clip align with the corresponding buttons on the tube assembly. Assembly 4 Attach drive shaft seal Instrument 351.718S Drive Shaft Seal, for RIA, sterile
RIA 2 (Reamer Irrigator Aspirator) Surgical Technique DePuy Synthes 3 Indications The DePuy Synthes RIA 2 System is intended for use in adults and adolescents (12-21 years) • To clear the medullary canal of the bone marrow and debris • To effectively size the medullary canal for the acceptance of an intramedullary implant or prosthesis
REAMER / IRRIGATOR / ASPIRATOR (RIA)
the Reamer Irrigator Aspirator system Fig 1a-b The Reamer Irrigator Aspirator system (a ) with attached power tool (b ). a b Prepared by members of the RIA Task Force. Last updated May 2017. 2 1Whath rtepovpdincahsfpua vpsiRmdsaIgmviaiApa1pIypeaWeeR(Iimeahs)ReIimeascsipy
The Reamer/Irrigator/Aspirator (RIA) system (Synthes, Inc., West Chester, PA) was developed as a simultaneous reaming and aspiration system to reduce the intramedullary pressure, heat generation, operating time, and systemic effects of reaming. It was designed with an aggressive one-pass reamer head which is connected to a hand-held reamer via ...
Reamer / Irrigator / Aspirator (RIA) Surgical Technique DePuy Synthes 11 Note: The drive shaft is properly attached when the hex flats are not visible. The helix is also visible when properly attached. Precaution: Improper assembly can result in product breakage, which may lead to surgical delay, bone damage, and/or adverse tissue damage.
Solution: The reamer-irrigator-aspirator (RIA) system is used to harvest large volumes of intramedullar bone graft for surgical procedures that require bone graft, including non-unions, delayed union, and bone loss. Surgical technique: The RIA device should be assembled prior to the surgical procedure. The greater trochanter is used as entry point.
Background: The reamer-irrigator-aspirator (RIA) is an innovation developed to reduce fat embolism (FE) and thermal necrosis (TN) that can occur during reaming/nailing of long-bone fractures. Since its inception its indications have expanded to include the treatment of long-bone osteomyelitis and as a harvester of bone graft/mesenchymal stem cells (MSCs).
1/4/2008 · The reamer irrigator aspirator (RIA) technique has been described as a method for bone graft harvesting in patients with osseous defects or non-unions where more than 20-25 mL of bone may be needed.1, 2 Early reports indicate reduced incidence and magnitude of pain, 3 which are common complications associated with obtaining an autograft from the iliac crest.
RIA 2 (REAMER IRRIGATOR ASPIRATOR) Introduction. The RIA 2 System is designed for reaming of the medullary canal for preparation of internal fixation, harvest of bone marrow, and/or clearing of debris. The RIA 2 System consists of disposable Reamer . Heads, Tube Assembly, Reaming Rod Seal, Graft Filter, Irrigation and Aspiration Tubes, and reusable
RIA 2 (Fig 1) is the next generation reamer-irrigator-aspirator device. Intended for use in adults and adolescents, its indications are to clear the medullary canal of bone marrow and debris, enlarge the medullary canal for the insertion of an intramedullary implant or prosthesis, to harvest morselized autogenous bone and bone marrow for bone grafting purposes, and to remove infected and ...
The Reamer-Irrigator-Aspirator: Roles and Evidence Supporting its use in Current Orthopaedic Practice Kevin M. Kuhn, Brian T. Barlow and David Dromsky Department of Orthopaedic Surgery, Naval Medical Center San Diego, USA Corresponding author: Kevin M. Kuhn, Department of Orthopaedic Surgery,
This video demonstrates correct surgical technique, tips, and tricks regarding application of the reamer-irrigator-aspirator for autologous bone graft harvest. The case presented describes treatment of a polytrauma patient who sustained an open tibial fracture with …
Reamer/Irrigator/Aspirator (RIA) Surgical Technique DePuy Synthes 17 Assembly. 1 Introduce RIA assembly into medullary canal Guide the reamer head over the reaming rod. Open the irrigation clamp to start liquid flow and ensure vacuum is operational.
1/10/2015 · Reamer-irrigator-aspirator bone graft and bi Masquelet technique for segmental bone defect nonunions: a review of 25 cases Injury , 41 ( Suppl 2 ) ( 2010 ) , pp. S72 - S77 Article Download PDF View Record in Scopus Google Scholar
Reamer Irrigator Aspiratorによる新しい自家骨採取法. 12:00 - 12:20. 小牧市民病院. 福田 誠先生. Reamer Irrigator Aspiratorによる新しい自家骨採取法. トップへ戻る.